Application
Single and dual-train, packaged plants for wastewater treatment
Capacity
Up to 110,000 GPD
(416 m3/day) at Average Daily Flow
Up to 220,000 GPD
(832 m3/day) at Maximum Daily Flow
Multiple Z-MOD M units can be linked together to efficiently and cost
effectively provide high quality permeate to a common permeate collection
pipe.
Application Dependent Options
| Influent System |
Grinder Pump |
Pumps and valves used to grind and transfer wastewater from EQ tank to
the process tank |
| Waste Transfer Pump System |
Pumps and valves used to transfer wastewater from the biological tank
to the membrane tank |
| Fine Screening System |
Fine screen, screenings handling and associated equipment |
| Influent Flow Measurement |
Magnetic Flow Meter used for measurement of incoming wastewater flow rate |
| Chemical Addition |
NaOCI Dosing System |
Dosing pumps and associated equipment used for cleaning organic fouling |
| Citric Acid Dosing System |
Dosing pumps and associated equipment used for cleaning inorganic scaling |
| Co-Nutrient Dosing System |
Dosing pumps and associated equipment used for increasing Total Nitrogen
Removal |
| Coagulant Dosing System |
Dosing pump and associated equipment for increased phosphorous removal |
| pH Control |
Dosing pump and analyzer required for pH control of the biological system |
| Biological Equipment |
Recirculation pump |
Return Activated Sludge Pump for improved TN removal |
| Process Tank Aeration System |
Duty/Standby Aeration Blowers for sustaining the biological system |
| Process Tank Diffuser System |
Diffusers and valves used for air ab in conjunction with the process tank
blower to increase the absorption of oxygen into the mixed liquor |
| Anoxic System Mixing |
Mixer and controls required to automatically mix the anoxic system |
| Effluent System |
Effluent Flow Measurement |
Magnetic Flow Meter used for measurement and flow totaling of effluent |
| Effluent Turbidity Meter |
Turbidity Meter and valves used for online turbidity monitoring |
| UV System |
Ultraviolet System used for disinfecting the effluent |
| Other |
Spare Pumps and Blowers |
Shelf Spares for pumps and blowers can be supplied for emergency maintenance |
| Allen-Bradley PLC |
Upgrade to Allen-Bradley PLC components and HMI from Koyo |
| ZenoTrac™ |
GE proprietary data analysis and tracking system |
| Commissioning |
ZENON trained personnel for plant start-up and operator training |
Z-MOD M System Configurations
| Model |
ADF (GPD) |
MDF (GPD)** |
Tie Point Connections |
Dimensions |
Operating Weight (lbs) |
| Influent |
Effluent |
Drain |
L |
W |
H |
| M4 |
20,000 |
40,000 |
2" |
1.5" |
3" |
9'8" |
4'2" |
9' |
11,000 |
| M8 |
40,000 |
80,000 |
3" |
2" |
4" |
12'5" |
4'2" |
9' |
15,000 |
| M2* |
10,000 |
20,000 |
1.5" |
1.5" |
3" |
11'10" |
6'5" |
9' |
22,000 |
| M4* |
20,000 |
40,000 |
2" |
2" |
3" |
11'10" |
6'5" |
9' |
22,000 |
| M8* |
40,000 |
80,000 |
3" |
2" |
4" |
11'10" |
6'5" |
9' |
22,000 |
| M16* |
80,000 |
160,000 |
3" |
3" |
6" |
15'6" |
7'3" |
9' |
29,000 |
| M44* |
110,000 |
220,000 |
3" |
3" |
6" |
15'6" |
7'3" |
9' |
29,000 |
Major Equipment Manufacturers
| Z-MOD M Equipment |
Manufacturer |
| Permeate pump |
G & L |
| Backpulse pump |
G & L |
| Submersible pumps |
ABS |
| Membrane Blower |
Rietschle |
| Process Blower |
Aerzen |
| Valves |
Keystone, Chemline |
| Chemical pumps |
Prominent |
| Flow and level measurement |
E & H |
| PLC components |
Koyo |